同步及负载分配

同步及负载分配

KSQ同步表(盘面安装)、KCQ同步继电器(导轨安装)、SL96C、SQE96C同步指示器、KRV43B电压比较继电器

0.00
0.00
  

KSQ同步表(盘面安装)、KCQ同步继电器(导轨安装)、SL96C、SQE96C同步指示器、KRV43B电压比较继电器

Synchronising and Load Sharing 


Megacon - the trendsetter in synchronisation control for paralelling or phasing of  AC supplies

Today Megacon uses the following two basic synchronisation control principles:

 

SYSTEM "S" - SECTOR SYNCHRONISATION

Bi-directional Check Synchronising Relay 

The system "S" guard is a low-differential Check Synchronising Relay.
Synchronising relay closes when phase differential is within set limits (sector "S") for a pre-set time ("t").
 
Sector synchronisation is the classical alternative for applications which allows that synchronisation accuracy and speed of synchronisation are interrelated.


Synchronisation accuracy (Df) can be calculated by following formula:

 
Df = (S : 360) / t (secs)
Example: Set phase angle (S) to 10 degrees and retention time (t) to 500mS to obtain an accuracy of Df:
(10/360) / 0,5 =  0,055Hz 

 
SYSTEM "P" - "SPOT-ON" SYNCHRONISATION

Uni-directional Fast and Accurate Synchronisation

The dynamically controlled system "P" provides the fastest "spot-on" synchronisation. Dynamic breaker closing time compensation assures precision 12 o’clock synchronisation, when frequency of incoming generator is slightly higher than busbar frequency.
 
Synchronising relay initiates generator breaker closure at moment "T", angle "a" is dynamically adjusted according the two systems frequency/phase differential.


This directional synchronisation relay allows operation when frequency of incomer is HIGHER than bus frequency. In this way incomer is protected against motoric operation during start-up.
 
To adapt the functionality of KSQ104F to any specific application, the direction of approach to synchronising  (LEAD, LAG or NEUTRAL) can be selected as required:
  • LEAD (incomer faster than bus)

  • LAG (incomer slower than bus)

  • NEUTRAL (bi-directional)

LEAD is generally the preferred mode. The synchronising relay will then operate when the frequency of the incomer is slightly HIGHER than the bus frequency. This is to avoid motoring of the incomer (entering reverse power condition) after the breaker is closed.


 
SECTOR Synchronisation
 
KSQ331x2
SECTOR SYNCHRONISING RELAY
(Panel mounting)
 
 
KCQ331x2
SECTOR SYNCHRONISING RELAY
(DIN Rail mounting)
 
 
KSQ332x2
SECTOR SYNCHRONISING RELAY WITH DEAD BUS FACILITY
(Panel mounting)
 
 
KCQ332x2
SECTOR SYNCHRONISING RELAY WITH DEAD BUS FACILITY
(DIN Rail mounting)
 
  
KSQ333x2
AUTOMATIC SYNCHRONISATION CONTROLLER
(Panel mounting)
 
 
KCQ333x2
AUTOMATIC SYNCHRONISATION CONTROLLER
(DIN Rail mounting)
 
 
KSQ333EJD52x
AUTOMATIC SYNCHRONISATION CONTROLLER
(Panel mounting)
 
 
KCQ333EJD52x
AUTOMATIC SYNCHRONISATION CONTROLLER
(DIN Rail mounting)
 

 

 
SPOT ON Synchronisation
 
KSQ104x2
"SPOT-ON" AUTOMATIC SYNCHRONISER
(Panel mounting)
 
 
KCQ104x2
"SPOT-ON" AUTOMATIC SYNCHRONISER
(DIN Rail mounting)
 
 
KSQ104EJD42x
"SPOT-ON" AUTOMATIC SYNCHRONISER WITH DEAD-BUS
(Panel mounting)
 
 
KCQ104EJD42
"SPOT-ON" AUTOMATIC SYNCHRONISER WITH DEAD-BUS
(DIN Rail mounting)
 
 
KSQ106x2
COMBINED “SPOT-ON” & SECTOR AUTOMATIC SYNCHRONISER
(Panel mounting)
 
 
KCQ106x2
COMBINED “SPOT-ON” & SECTOR AUTOMATIC SYNCHRONISER
(DIN Rail mounting)
 

    

 

Bus/Gen Coupler

 
KSQ332EJD12
CHECK SYNCHRONISER RELAY & BUS/GENERATOR COUPLER
(Panel mounting)
 
 
KCQ332EJD12
CHECK SYNCHRONISER RELAY & BUS/GENERATOR COUPLER
(DIN Rail mounting)
 
   
KSQ332EJD22
BUS COUPLER RELAY WITH DEAD BUS AND/OR DEAD INCOMER
(Panel mounting)
 
 
KCQ332EJD22
BUS COUPLER RELAY WITH DEAD BUS AND/OR DEAD INCOMER
(DIN Rail mounting)
 
   
KSQ333EJD32
BUS COUPLER RELAY WITH DEAD BUS AND/OR DEAD INCOMER
(Panel mounting)
 
 
KCQ333EJD32
BUS COUPLER RELAY WITH DEAD BUS AND/OR DEAD INCOMER
(DIN Rail mounting)
 

 

 
Sync/Gen Controller
 
KSQ304E2
AUTOMATIC CO-GENERATION MANAGEMENT SYSTEM
(Panel mounting)
 
 
KSQ304EG2
EMERGENCY/STANDBY GENERATOR MANAGEMENT SYSTEM
(Panel mounting)
 


 
Synchronisation Indicators
 
SL96C
Lamp Synchroscope
(Panel mounting)
 
 
SQE96C
LED Synchroscope
(Panel mounting)
 
 

 
KRV43B - Voltage Comparator
  • Voltage Comparator Relay

The KRV43B is used in conjunction with the KSQ104 and KSQ105 automatic synchronisers.

The relay output will only close when the voltage difference is within the set parameters. This output is connected to the inhibit function of the associated synchroniser.

The factory set default value is +/- 2% of nominal.